Liquid Crystal-related Device - Small Rubbing Device “Type: MRM-100”

Product Details
small device with specifications excellent even for developmental applications.
The purpose of the Small Rubbing Device “Type: MRM-100” is to orientate liquid crystal molecules by rubbing the film formed on glass substrates in liquid crystal panels.
It is compact, which provides excellent functionality when using it for experiments, research and prototypes.
[Main Specifications]
○Table size: 100×100mm
○Table movement speed: 600mm/min (variable)
○Table revolution scope:±45° (Micro-head operation) Optional
○Table vertical stroke range: 10mm (Micro-head operation)
Product Specifications
[Specifications]
○Table size:100×100mm
○Table movement speed: 600mm/min (variable)
○Table revolution scope: ±45° (Micro-head operation) Optional
○Table vertical stroke range: 10mm (Micro-head operation)
○Table lifting mechanism: Test pieces lower and recede on return trip during reciprocating operation
○Roll width: 240mm
○Roll diameter: φ48mm
○Roll revolution speed: Max. 1400rpm
○Roll revolution scope: ±45°
○Utilities: Power source 100V 500W; Compresses air 0.5MPa
○External dimensions: 570 wide ×700 long ×730mm tall; Approx. 80kg
○Installation dimensions: 1,050mm long and 1,050mm tall when opening/closing cover
*The aforementioned items may vary depending on purchased specifications.